The GMS800 is a product family of extractive gas analyzers which can measure more than 60 different gas components. The GMS800 is characterized by its modular design: 6 analyzing modules, one gas module, I/O modules and a control unit. Standardized 19” plug-in housings can be used for economical system integration. In harsh industrial environments, wall-mounted housings with approvals for Ex-zones according to ATEX are used.
Emission monitoring according to EN 15267 and process gas measurements, even in explosion-hazardous areas
Emission monitoring with very low concentrations
Measurement of sulfur compounds in process gases
Measurement of very low concentration in hydrogen or hydrocarbons
Device properties:
6 different analyzer modules
4 different types of enclosures
Gas module with sample gas pump and/or control sensors
New enclosure type for easy and quick integration
Remote diagnosis via Ethernet with SOPAS ET software
Benefits
Suitability tested according to EN 15267 and EN 14181
Installation in non-explosion-hazardous areas and explosion-hazardous areas (Zones 1 and 2 according to ATEX) possible
Modular design for minimum service and maintenance as well as easy upgrading of existing installations
Adjustment possible without test gases via optional adjustment unit
Influence of ambient temperature very minimal thanks to thermostatic measurement modules
Ar, CH4, CH3OH, C2H2, C2H2F4, C2H4, C3H6, C3H8, C4H6, Cl2, CO, CO2, COCl2, COS, CS2, H2, H2S, He, NH3, NO, N2O, NO2, O2, SF6, SO2, other components on request
Performance-tested measurands
CH4, CO, CO2, NO, NO2, O2, SO2, N2O
Ambient temperature range
+5 °C ... +45 °C
Ambient humidity
≤ 95 % Relative humidity; non-condensing
Degree of protection
IP65
Hazardous area approvals
GMS820P: IECEx: Ex db eb [ia] IIC T6 ATEX: II 2G Ex db eb [ia] IIC T6 Gb II 2G Ex db eb IIC T6 Gb GMS84x: IECEx: GMS841: Ex nA nC IIC T4 Gc GMS841: Ex nA nC [ia Ga] IIC T4 Gc ATEX: GMS841: II 3G Ex nA nC IIC T4 Gc GMS841: II 3G Ex nA nC [ia Ga] IIC T4 Gc NEC/CEC (US/CA): GMS842: Class I, Division 2, Groups A, B, C and D; T4 GMS842: Ex nA nC IIC T4 Gc GMS842: Ex nA nC [ia Ga] IIC T4 Gc GMS842: Class I, Zone 2 AEx nA nC IIC T4 Gc GMS842: Class I, Zone 2 AEx nA nC [ia Ga] IIC T4 Gc
The GMS800 is a product familiy of extractive analyzers which
can measure more than 60 different gas compounds. The GMS800 is
characterized by its modular design: 6 analyzing modules,
one gas module, I/O modules and an operating unit.
Oil and gas – solutions for the oil and gas industry
Industry Solution (SO)
English version - 01/2025
New version available in English
Endress+Hauser offers the best solutions through a huge range of products and systems to measure and perform even under the most rigorous operating conditions.
The repair service ensures that the functionality of the GMS800 emission monitoring solution is restored quickly. The device is also given a general overhaul in order to prevent future failures.